Faults and corrective measures for the equipment of the charcoal machine

Faults and corrective measures for the equipment of the charcoal machine
 
First, the console power indicator is off
 
the reason:
1, the charcoal machine power is not connected;
2, the fuse blows;
3, the indicator light is bad.
 
Corrective Action:
1, pick up the mechanism of charcoal machine power line;
2, replace the fuse;
3, replace the indicator light gun.
 
Second, charcoal molding machine motor does not start
 
the reason:
1. The control button of the charcoal machine is damaged;
2, lack of a phase;
3, voltage, frequency does not match.
 
Corrective Action:
1, replace the charcoal machine control button;
2, connect the power cord;
3, check the voltage frequency.
 
Third, the heating temperature rises slowly to less than 350 degrees
 
the reason:
1, charcoal machine power supply voltage is low;
2, charcoal molding machine resistance heating ring damage;
3, charcoal machine to replace the heating ring wire model is wrong.
 
Corrective Action:
1, check the charcoal machine voltage;
2, replace the charcoal resistance heating ring;
3. Replace the charcoal machine wires as required.