Faults and corrective measures for the equipment of the charcoal machine
First, the console power indicator is off
the reason:
1, the charcoal machine power is not connected;
2, the fuse blows;
3, the indicator light is bad.
Corrective Action:
1, pick up the mechanism of charcoal machine power line;
2, replace the fuse;
3, replace the indicator light gun.
Second, charcoal molding machine motor does not start
the reason:
1. The control button of the charcoal machine is damaged;
2, lack of a phase;
3, voltage, frequency does not match.
Corrective Action:
1, replace the charcoal machine control button;
2, connect the power cord;
3, check the voltage frequency.
Third, the heating temperature rises slowly to less than 350 degrees
the reason:
1, charcoal machine power supply voltage is low;
2, charcoal molding machine resistance heating ring damage;
3, charcoal machine to replace the heating ring wire model is wrong.
Corrective Action:
1, check the charcoal machine voltage;
2, replace the charcoal resistance heating ring;
3. Replace the charcoal machine wires as required.